13
5 Connecting to power supply
VEGAMET 141 • 4 … 20 mA
63728-EN-210129
Connect the device as described in the following wiring plan.
5.4 Wiring plan
67 68 69
64 65 66
61 62 63
1 2 3
41 42
+ -
91 92
L+ N-
1
3
4
7
6
5
2
Fig. 3: Wiring plan VEGAMET 141
1 Sensor input (active/passive)
2)
2 HART sockets for connection of a VEGACONNECT
3 4 … 20 mA current output
4 Voltage supply of the controller
5 Relay output 1
6 Relay output 2
7 Relay output 3
Connecting
2)
Passive input not available for Ex version