EasyManua.ls Logo

Vega VEGAMET 141 - Switch-On Phase

Vega VEGAMET 141
20 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
14
5 Connecting to power supply
VEGAMET 141 • 4 … 20 mA
63728-EN-210129
Detail sensor connection 1
3
1
5
4
2
+-+-
1 2
3
1 2
3
Fig. 4: Sensor input connection for two-wire/four-wire sensor (active/passive)
1 Active input with sensor supply for two-wire sensor
2 Passive input without sensor supply for four-wire sensor
3)
3 Two-wire sensor
4 Four-wire sensor
5 Voltage supply for four-wire sensor
5.5 Switch-on phase
Afterswitchingon,thedevicerstcarriesoutashortself-check.
Internal check of the electronics
Output signals are set to failure, background lighting of the display
lights red
The current measured values are then displayed and transmitted to
the outputs. The background lighting of the display changes to white.
3)
Passive input not available for Ex version