9MeasuredvaluetransmissiontoaWEB-VVserver
RS232/Ethernet connection • VEGAMET 391/624/625, VEGASCAN 693, PLICSRADIO C62
30325-EN-130701
9.4 Signal conditioning instrument (Ethernet) in
LAN
Thisalternativeisusedifacompanynetworkwithinternetaccess
isavailable.Anynumberofsignalconditioninginstrumentscanbe
connectedtoWEB-VV.Thesignalconditioninginstrumentsmustbe
equippedwiththeEthernetinterfaceoption.Whenaddressingisdone
viaDHCP,asuitableHostnameshouldbeassigned.Asanalterna-
tive,auniqueIPaddresssuitabletothenetworkcanbeassigned.Yo u
canndfurtherinformationinchapter"Network settings".
Prerequisites for setup:
•
PCwithPACTware andsuitableDTMaswellasaccesstothe
signalconditioninginstrumentviaVEGACONNECTorLAN
•
Subnetmask,standardgatewayandDNSserverdofthecompany
network
•
httpport80mustbeactivatedforanInternetconnection
StartPACTwar eandmakeaconnectiontothesignalconditioning
instrument.Selectthemenuitem"Instrument settings - LAN/Internet".
Carryoutthefollowingstepsasshowninthefollowingillustrations.
1. GiveeverysignalconditioninginstrumentauniqueIPaddress
thatyouhavereceivedfromyourresponsiblenetworkadministra-
tor.Thesubnetmaskmatchingyournetworkandthestandard
gatewayalsocomefromyournetworkadministrator.Alternatively,
youcanusetheDHCPfunctionifaDHCPserverisavailablein
your network.
Fig. 21: Allocate IP address
2. EntertheIPaddressofyourDNSserverunder"Instrument set-
tings - DNS Server".