EasyManua.ls Logo

Vega VEGAPULS 51K - Technical Data; Power Supply and Consumption

Default Icon
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VEGAPULS 51K … 54K 51
21750-EN-031222
1000
900
800
700
670
600
500
400
300
250
200
100
0
14
20
25
30 35
15
29
36
V
975
720
25,5
19,5
Adjustment
resistance
(HART
®
and
VEGACONNECT)
max. voltage limit
Ex ia sensors
max. voltage limit
non-Ex and
Ex d ia sensors
min. voltage limit when using the HART
®
adjustment resistance:
- non-Ex and Ex ia sensors
- Ex d ia sensors
Non-Ex and Ex ia
Exd ia
7 Technical data
7.1 Technical data
Power supply
Power supply
- four-wire sensor 24 V DC (20 … 72 V DC)
(non-Ex and Ex d ia) 230 V AC (20 … 253 V AC), 50/60 Hz
fuse 0.315 A TR
- two-wire sensor 24 V DC (14 … 36 V DC)
- two-wire Ex ia sensor 24 V DC (14 … 29 V DC)
- two-wire Exd ia sensor 24 V DC (20 … 36 V DC)
Permissible residual ripple of the power
supply with two-wire sensors
- 0 … 125 Hz 1 V
ss
- 125 Hz … 500 Hz 1.0 0.01 V
ss
declining linearly
- 500 Hz … 10 kHz 0.01 V
ss
Power consumption
- four-wire sensor max. 130 mA
- two-wire sensor max. 22.5 mA
Power consumption
- four-wire sensor max. 2.1 W; 7.5 VA
- two-wire sensor 55 810 mW
Load
- four-wire sensor max. 500 Ohm
- two-wire sensor see diagram
Technical data
max. load non-Ex
max. load Ex d ia
max. load Ex ia

Related product manuals