EasyManua.ls Logo

Vega VEGAPULS 51K - Safety-Related Characteristics

Default Icon
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
68 VEGAPULS 51K … 54K
21750-EN-031222
0 1 2 3 4 5
years
T
proof
= 1 year
T
proof
= 3 years
T
proof
= 5 years
0,00·10
-
2
0,24·10
-
2
0,48·10
-
2
PFD
avg
0,36·10
-
2
0,60·10
-
2
0,12·10
-
2
Supplement
6 Safety-related characteristics
The failure rate of the electronics and the antenna system was determined by an FMEDA (Fail-
ure Mode, Effects and Diagnostics Analysis) acc. to IEC 61508. The number values are based
on an output current tolerance of max. 2 %.
Architecture 1oo1D SIL 2
VEGAPULS 51 Overfill protection Dry run protection Individual level
VEGAPULS 52
VEGAPULS 53
VEGAPULS 54
VEGAPULS 56
HFT 0
SFF > 86%
PFD
avg
1)
< 0.12 •10
-2
with T
Proof
= 1 year
2)
< 0.60 •10
-2
with T
Proof
= 5 years
PFH [1/h]
3)
< 0.28 •10
-6
Failure reaction time T
Reaction
= 60 sec
Max
Min
1)
PFD
avg
this value correlates almost linearly to the operating time. It is only valid for the corresponding
selection circuit.
2)
T
Proof
is the interval after which a periodically recurring complete function test (to check the safety function)
must be carried out.
3)
PFH is valid for the stated Failure reaction time T
Reaction
of the measuring system. This means that the failure
tolerance time of the complete system must be higher than T
Reaction
.

Related product manuals