EasyManua.ls Logo

Vega VEGAPULS 54K - Aluminium Housing: Exd Terminal Compartments

Default Icon
72 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
30 VEGAPULS 51K … 54K
21750-EN-031222
Electrical connection
ATEX
Supply: 20...36V DC/4...20mA HART
ser.no ********
R
FM
APPROVED
R
-+
21
IS
GND
-+
ESC
ESC
+
-
OK
OK
1 2 C 5678
(+) (-)
L1 N
Commu-
nication
Display
12 C 5 6 7 8
Power supply
Two-wire EEx d terminal compartment
(opening in Ex atmosphere not allowed)
Two-wire adjustment module terminal
compartment
(opening in Ex area permitted)
Exd terminal compart-
ment
1
/
2
“ NPT EEx d
diameter of the
connection cable
to the Exd
terminal com-
partment
3.1…8.7 mm
(0.12…0.34 inch)
Exd safe connection to the
Exd terminal compartment
1
/
2
“ NPT EEx d
diameter of the
connection cable
3.1…8.7 mm
(0.12…0.34 inch))
Version with aluminium housing and pressure-tight encapsulated terminal
compartment
Locking of the cover
4...20mAsupply
20...72V DC
20...250V AC
HART
ser.no ********
12
+-
R
+-
543
IS
GND
R
-+-+
4 ... 20 mA
ESCESC
+
-
OKOK
1 2 C 5678
(+) (-)
L1 N
Commu-
nication
Display
12 C 5 6 7 8
Power supply
Four-wire EEx d terminal compartment Four-wire adjustment module terminal
compartment
(opening in Ex area permitted)
Exd terminal
compartment
1
/
2
“ NPT EEx d
diameter of the
connection cable
to the Exd
terminal com-
partment
3.1…8.7 mm
(0.12…0.34 inch)
Exd safe connection to the
Exd terminal compartment
1
/
2
“ NPT EEx d
diameter of the
connection cable
to the Exd terminal
compartment
3.1…8.7 mm
(0.12…0.34 inch)
Locking of the cover