Installation / Operation / Maintenance
Manual
GASGUARD
®
AP10
Source Systems
Manual Part Number: 123223
Edition: Rev-1
Question and Answer IconNeed help?

Do you have a question about the Versum Materials GASGUARD AP10 and is the answer not in the manual?

Summary

Section 1: Safety Warnings

General Safety Precautions

Details general warnings for inert gases, pressure, electricity, falling equipment, cylinder handling, and pinch hazards.

Personal Protective Equipment (PPE)

Specifies required PPE for operating and maintaining the GASGUARD system.

Detailed Hazard Warnings

Outlines specific hazards including toxic, corrosive, flammable, oxidizer, inert gases, pressurized, cylinder handling, and electrical.

Section 2: Dimensions and Mounting

Section 3: Tubing Connections

Exhaust and Leak Detection Systems

Outlines cabinet exhaust requirements and mandatory hazardous gas leak detection.

Section 4: Electrical Connections

Section 5: Helium Leak Testing

Helium Leak Testing Procedures

Explains methods (inboard/outboard), factory testing, and field rechecks for leak integrity.

Manual Mode Leak Checking

Details performing leak tests in manual mode, including critical safety warnings and procedures.

Section 6: Source System Functional Checklist

Section 7: System Description

Section 8: Operating Procedures

Emergency Shutdown and Controller Operation

Covers emergency shutdown procedures and basic operation of the cabinet controller interface.

Cylinder Handling Procedures

Details step-by-step procedures for changing inert purge and process gas cylinders safely.

System Startup and Manual Operation

Guides new system startup, including purging and controller operations in manual mode.

Section 9: Troubleshooting

Alarm Condition Troubleshooting

Covers troubleshooting for typical alarms including excess flow, pneumatic pressure, cylinder pressure, vacuum, and vent pressure.

Cylinder and Connection Issues

Troubleshoots cylinder leaking, standby leaks, high pressure at connections, and process/purge delivery issues.

Section 10: Maintenance

Section 11: System Specifications

Appendix D Supplemental Information for GASGUARD Acetylene Source Systems

Versum Materials GASGUARD AP10 Specifications

General IconGeneral
ModelGASGUARD AP10
ManufacturerVersum Materials
Gas CompatibilityVarious high-purity gases
Flow RateVaries by application
Purge CapabilityYes
Power Requirements100-240 VAC, 50/60 Hz
Operating PressureVaries by application
DimensionsVaries depending on configuration
WeightVaries depending on configuration