Do you have a question about the Victron energy BMV-501 and is the answer not in the manual?
Current Measurement Range | ±500A |
---|---|
Display Type | LCD |
Current Measurement Resolution | 0.1 A |
Temperature Measurement Resolution | 0.1 °C |
Amp Hour Resolution | 0.1 Ah |
Operating Temperature Range | -20 to +50 °C |
Supply Voltage Range | 6.5 to 70 V |
Voltage Measurement Resolution | 0.01V |
Shunt Voltage Drop | 50mV @ 500A |
Introduces the BMV-501 battery monitor, detailing its functionality, operation, and technical features.
Explains why monitoring is crucial for battery longevity and performance, highlighting factors affecting battery life.
Details how the BMV-501 measures battery status, including current flow, capacity, Peukert efficiency, and temperature compensation.
Essential safety guidelines for working with lead-acid batteries, covering gas hazards, acid contact, and electrical short circuits.
Explains the Charge Efficiency Factor and its impact on battery capacity, noting the BMV-501's automatic calculation.
Guides on calculating and setting the Peukert exponent for accurate capacity readings at different discharge rates.
Details the voltage, current, and time parameters used to determine a fully charged battery state for synchronization.
Describes methods for synchronizing the BMV-501 with the battery and charger for accurate state-of-charge readings.
Provides an overview of the BMV-501's setup functions (F01-F20) and guidance on recommended adjustments.
Explains key displayed parameters: Voltage, Current, Consumed Amphours, State-of-Charge, Time-to-go, and Temperature.
Explains the meaning of the 'CHARGE BATTERY', 'BATTERY FULL', and 'CHARGE BATTERY FULL' flashing indicators on the display.
Details how the BMV-501 stores and allows recall of specific events and historical data points (H01-H10).
Describes connecting the BMV-501 to a PC for advanced configuration, data access, and testing via an optional interface kit.
Explains the super-lock function for password-protecting setup menus and historic data, accessible only via PC-link.
Lists common operational problems like no display, incorrect polarity, and system resets, with suggested solutions.
Provides solutions for inaccurate state-of-charge, time-to-go, temperature, and voltage readings, and setup lock issues.
Details accuracy, dimensions, weight, materials, included items, and optional accessories for the BMV-501.
Confirms the BMV-501's compliance with European Union EMC directives and harmonized standards.