15.4.1. Configuration of RV-C out devices
RV-C out devices can be configured from the Devices submenu in the VE.Can port menu.
The Devices submenu contains all devices of the RV-C network including RV-C out devices. The latter are identified by their
[VRM# instance], which can be used to identify the "real" devices from the root menu of the GX device. The hexadecimal on the
right hand side is the Source Address.
When you enter the submenu of an RV-C device, you will see general RV-C device information and more importantly the
configuration menu if you scroll down to the bottom of the page. Viewing the configuration menu requires at least user and
installer access level, see chapter Menu structure and configurable parameters [37].
The instance for the corresponding DGNs can be changed in the Configuration submenu.