20.1.3. DGN 60928 Unique Identity Numbers
The GX device will assign an individual Unique Identity Number to each virtual device. Change it only when using multiple GX
devices in one RV-C network.
The Unique Identity Number is used for the GX internal CAN-bus device "database" to compare devices during address
determination. To avoid clashes on CAN-Bus you must set the second GX device to the unique identity range of 1000-1499.
This can be done by setting the unique identity selector to 2 (2 * 500). This works exactly the same as for VE.Can, see the PGN
60928 NAME Unique Identity Numbers [95] section.
20.1.4. RV-C in
Tanks
Tested with Garnet SeeLeveL II 709 and tanks from the RV-C out function of another GX device.
Batteries
Lithionics is the only supported RV-C battery (including DVCC support).
20.1.5. Device Classes
This section provides a basic overview of how each device class will participate in the RV-C specification. In any case, "Level 1"
integration is largely supported (basic operation), with case-by-case enhancements.
AC standalone Chargers
• The AC-based charger class reports its operational status and configuration status using the CHARGER_xx group of RV-C
messages. User control must include basic on/off switching via RV-C as well as adjusting shore (AC) power limits.
AC standalone Inverters
• This class of AC inverters reports its operational status using the INVERTER_xx group of RV-C reports. Incoming command is
limited to on/off (enable/disable) via RV-C.
AC Charger / Inverter
• Combined inverter/charger - reports both CHARGER_xx and INVERTER_xx messages.
Solar Controllers
• Solar chargers will report their operational status in real time.
SOC Meters
• SOC meters can be used to report current battery health via RV-C: voltage, current, temperature, SOC, etc. RV-C requires that
only ONE device speaks for a given battery at a time, so if a proper BMS is installed, that will be the data source.
BMS (Victron, or Victron 3rd party supported)
• In many cases, the battery(s) in the system will be directly attached to a Victron Cerbo GX or Cerbo-S GX, either via Victron
equipment or via supported 3rd party compatible BMSs. Such batteries should be represented into the RV-C environment via
the DC_SOURCE_STATUSxx messages.
Tank Level meters
• Tank meters will be translated into RV-C messages, carrying forward the existing tank ID/ VRM Instance numbers.