EasyManua.ls Logo

Victron energy Color Control GX - Battery State of Charge (SoC) Setup

Victron energy Color Control GX
131 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Item Default Description
Enable password check Choose password to allow Remote Console access.
Enable on VRM No No / Yes - Enabling on VRM will allow connection to the CCGX
from anywhere via the VRM portal. See also Troubleshooting
Remote Console on VRM [71]
Remote Console on VRM -
status
- Displays the connection state of the VRM Remote Console
Feature: Online, Offline, Disabled.
Enable on LAN No No / Yes - Enabling will allow direct connection to the CCGX
by typing its IP address or Venus.local into a web browser,
or in VictronConnect when connected to the same network.
Only enable this function on trusted networks. Disable password
check, or set password first.
System setup
System name Automatic Select the system name - presets or user defined
AC input 1 Generator Select Not available, Generator, Grid or Shore power. Note:
additional configuration is required for complete setup of these
options.
AC input 2 Grid Same choices as above.
Monitor for grid failure Disabled Monitors for loss of AC-input and triggers an alarm if detected.
Alarm is cleared when the AC-input is reconnected.
Battery monitor Automatic Select the SoC source. This function is useful where there is
more than one BMV. Options: Automatic, No battery monitor and
available battery monitor sources. For more details see Battery
state of charge (SoC) [44].
Has DC system Disabled Enable this for boats, vehicles and installations with DC loads and
chargers - in addition to Multi and MPPT chargers. This won't
be applicable to most off-grid installations; and any discrepancy
between the DC current measured by the Multi, and by the BMV,
will be attributed to a 'DC system'. This may be power-in from an
alternator, or power-out from a pump, for example.
A positive value indicates consumption. A negative value
indicates charging, for example by an alternator.
Note that the value shown will always be an approximation, and is
affected by the variation in sample rate between elements of the
system.
Battery Measurements Not set Use this menu to define which battery measurement to see on the
VRM portal and the MFD HTML5 app.
System status On/Off The following parameters are diagnostic flags only. See The
System Status Menu [46] chapter for details
Synchronise VE.Bus SoC with battery
Use solar charger current to improve VE.Bus SoC
Solar charger voltage control
Solar charger current control
BMS control
DVCC - Read full feature description [58]
DVCC Disabled Enabling DVCC changes a GX device from a passive monitor into
an active controller. Default setting is No, unless a compatible
BMS-Can managed battery is connected, then setting is set and
locked to manufacturers specification.
Limit charge current Disabled User-configurable system wide maximum charge current setting
in Amps.
Limit managed battery
charge voltage
Disabled Only use this option for 15s Pylontech batteries on initial
balancing. Using it for other purposes may have undesirable side
effects.
SVS - Shared voltage
sense
Disabled The GX device automatically selects the best available voltage
measurement and shares it with other connected devices.