10.5. Alarm status monitoring
The Alarm status monitoring page can be accessed from Device List → [Multi or Quattro] → Alarm status. It displays diagnostic
information on specific parameters to help with troubleshooting and provides additional information on the VE.Bus error 8/11.
10.6. VE.Bus alarm setup menu
When using a VE.Bus system, it is possible to configure the severity of problems on the VE.Bus system that should cause a
notification to show up on the Color Control GX (and make it beep).
To change the VE.Bus alarm & warning notifications, proceed as follows:
1. On the Remote Console, go to Device List → [your VE.Bus product] → Alarm setup
2. Choose between the following notification settings for each alarm:
Disabled: The CCGX will never beep or show a notification. Not recommended.
Alarm only (default): The CCGX will only beep and show a notification when the VE.Bus system switched off in an alarm
condition. Warnings are ignored.
Alarm & warnings: The CCGX will beep and show a notification on all selected alarms and warnings.
3. Scroll to the bottom of the list and enable or disable VE.Bus error notification.
When all done, don't forget to change the access level to user when required.
10.7. Device menu
The Device menu (Device List → [Multi or Quattro] → Device) offers device-related parameters such as custom name setting,
firmware version, serial numbers (in the sub-menu) and more that can be used for diagnostic.
Color Control GX Manual
Page 57 VE.Bus Inverter/charger monitoring