4.) Bias adjustment :
Set the Contrast
to 70Adjust the Brightness to 100.
5.) Gain adjustment :
Move cursor to “-F-” and press MENU key
AAdjust 9300 color-temperature
(1)Switch the CA-210 to xyLv -Mode (with press “MODE” button )
(2)Switch the MEM. channel to Channel 1 ( with up or down arrow on CA-210 )
(3) The LCD-indicator on CA-210 will show x=0.283±0.003, y=0.298±0.003,
Lv143cd/m
2
(4) Adjust the R G B of color3 on factory window until CA210 indicator reached
x=0.283±0.003, y=0.298±0.003, Lv143cd/m
2
BAdjust 7500 color-temperature
(1)Switch the CA-210 to xyLv -Mode (with press “MODE” button )
(2)Switch the MEM .channel to Channel 1( with up or down arrow on CA-210 )
(3) The LCD-indicator on CA-210 will show x=0.299±0.003, y=0.316±0.003,
Lv165 cd/m
2
(4)Adjust the R G B of color3 on factory window until CA210 indicator reached
x = 0.299±0.003; y = 0.316 ±0.003; Lv165cd/m
2
CAdjust 6500 color-temperature
(1)Switch the CA-210 to xyLv -Mode (with press “MODE” button )
(2)Switch the MEM .channel to Channel 1 ( with up or down arrow on CA-210 )
(3) The LCD-indicator on CA-210 will show x=0.313±0.003, y=0.329±0.003,
Lv187cd/m
2
(4) Adjust the R G B of color3 on factory window until CA210 indicator reached
x=0.313±0.003, y=0.329±0.003, Lv187 cd/m
2
DAdjust 5000 color-temperature
(1)Switch the CA-210 to xyLv -Mode (with press “MODE” button )
(2)Switch the MEM .channel to Channel 1( with up or down arrow on CA-210 )
(3) The LCD-indicator on CA-210 will show x=0.346±0.003, y=0.359±0.003,
Lv165 cd/m
2
(4)Adjust the R G B of color3 on factory window until CA210 indicator reached
x = 0.346±0.003; y = 0.359±0.003; Lv165 cd/m
2
EAdjust SRGB color-temperature
(1)Switch the CA-210 to xyLv -Mode (with press “MODE” button )
(2)Switch the MEM .channel to Channel 1 ( with up or down arrow on CA-210 )
(3) The LCD-indicator on CA-210 will show x=0.313±0.003, y=0.329±0.003,
Lv187 cd/m
2