6000V 200 ampere ring wave transient test with no
damage
Power Supply Line Surge Immunity
Shall be able to withstand 1.5 times nominal line
voltage for one cycle with no damage
Power Supply Missing Cycle Immunity
Shall be able to function properly, without reset or
visible screen artifacts, when ½ cycle of AC power is
randomly missing at nominal input
Power Supply Acoustics
The power supply shall not produce audible noise that
would be detectable by the user. Audible shall define
to be in compliance with ISO 7779 (DIN
EN27779:1991) Noise measurements of machines
acoustics. Power Switch noise shall not be considered
US Type Power Cable
Separate 3-prong NEMA 5-15P type plug. Length =
1.8m. Connects to display.
Color = Black
European Type Power Cable
Schuko CEE7-7 type plug.
Length = 1.8m, Connects to display.
Color = Black
CCC Type Power Cable
Separate 3-prong type plug.
Length = 1.8m. Connects to display.
Color = Black
PSE Type Power Cable
Separate 2-prong NEMA 1-15P type plug. Length =
1.8m. Connects to display.
Color = Black
Power Saving Operation(Method) VESA DPMS Signaling
Power Consumption
On Mode- W/O Audio < 43W (Typ) / 48W (Max)
On Mode- W/Audio < 50W (Typ) / 55W (Max)
Saving Mode < 2 W@230VAC 50HZ
Off Mode < 1 W @230VAC 50Hz
(DC Power Off; Meet to Energy Star Ver4.0 Tier2)
Recovery Time On Mode = N/A, Active Off < 3 sec
4-4 ELECTRICAL REQUIREMENT
Horizontal / Vertical Frequency
Horizontal Frequency 24 – 82 KHZ
Vertical Refresh Rate 50 – 85* HZ
Maximum Pixel Clock 150 MHz
Sync Polarity Independent of sync polarity.
Timing Table
Analog
Item
Timing
Separated
Composite
SOG
Digital - TMDS
Remark
1 640 x 350 @ 70 Hz, 31.5 KHz