Rules for installing the burglar alarm system
9. Scheduled maintenance of the back-up batteries
When there is the burglar alarm system it is essential to perform scheduled maintenance on all the batteries in
the back-up devices, sirens and radio frequency.
The burglar alarm system
The burglar alarm system can include up to 60 devices divisible into 30 groups or 9 distinct zones and, in combi-
nation with contact interfaces and radio frequency interfaces, will control technical alarms or allow the integration
of RF sensors installed in all those locations where it may not have been possible to prewire the building. Since
burglar alarm systems must remain powered up even in the absence of mains voltage, the devices in question
belong to Line 0 (Area 0) and are guaranteed auxiliary power in the event of an outage occurring.
The system is activated/deactivated/partitioned by means of numeric keypads, transponders or radio remote
controls and powered by way of one or two adapters and one or two back-up units (according to demand); as in
the case of the automation system, the burglar alarm system can be customized to meet different requirements,
such as the nature and layout of the rooms, the operating modes of the system, and the parameters of the various
components.
Example of burglar alarm system
Digital keypad01807 back-up unit
01809 + batteries
Bus + -
Contact
interface
01820,
01822,
01823,
01825,
01826,
01821
N/C contacts
Control
unit
01942
GSM communicator
01806
Outdoor
siren
Bus
IR detector Contact interface Gas stop detector
01401
Power supply unit
230 V~L N
By-me burglar alarm system data
Maximum number of devices 60
Number of groups 30
Maximum number of distinct zones 9