Home Automation System Guide
7
Rules for installing the By-me system
6. Installing By-me controls
Check the correct direction (up/down) of installation of the By-me automation controls to avoid feature reversal
(On/Off, up/down and adjustment) when programming.
7. Resetting the devices when first switching on the control unit
After first switching on the By-me control unit, always manually reset all the automation and speaker system
devices in the system. This will avoid potential issues related to the same addresses being present in the
devices in the field.
BUS line The insulation of the two cores, tested
in accordance with CEI 20-20/2
standard, guarantees electrical
insulation from the power cables at
230 V~
The outer sheath
guarantees 400 V
electrical insulation
between terminals and
earth, in compliance
with
CEI UNEL 36762
Load connection terminals
(devices with actuator only)
Connecting the Bus cable
Control unit
The control unit 21509
can be flush-mounted in
a box V71303 (V71703
for light walls) or on a DIN
rail (60715 TH35) with the
mounting frame V51921
provided