I&M data Access Preset Explanation
SOFTWARE_REVISION read (4Byte) Firmware version
Vxyz
Firmware version of the module.
An increase of the firmware version
also increases the hardware revision
REVISION_COUNTER read (2Byte) 0000 hex reserved
PROFILE_ID read (2Byte) F600 hex Generic Device
PROFILE_SPECIFIC_TYPE read (2Byte) 0003 hex at I/O modules
IM_VERSION read (2Byte) 0101 hex Information about the version of the
I&M data. (0101 hex = Version 1.1)
IM_SUPPORTED read (2Byte) 001F hex Information about available I&M-
Data
(IM_INDEX: 650000 ...65004)
Maintenance data 1: IM_INDEX: 65001
TAG_FUNCTION read / write
(32Byte)
–
Clear module ID inside the system
TAG_LOCATION read / write
(22Byte)
–
Location of installation of the module
Maintenance data 2: IM_INDEX: 65002
INSTALLATION_DATE read / write
(16Byte)
–
Date and if applicable time of
installation of the module
RESERVED read / write
(38Byte)
–
reserved
Maintenance data 3: IM_INDEX: 65003
DESCRIPTOR read / write
(54Byte)
–
Commentary to the module
Maintenance data 4: IM_INDEX: 65004
SIGNATURE read / write
(54Byte)
–
Commentary to the module