Chapter 1 Basics and Assembly Manual VIPA System SLIO
1-22 HB300E - PS-CM - Rev. 11/28
General data
Conformity and approval
Conformity
CE 2006/95/EG Low-voltage directive
Approval
UL UL 508 Approval for USA and Canada
others
RoHs - Product is unleaded
Protection of persons and device protection
Type of protection - IP20
Electrical isolation
to the field bus - electrically isolated
to the process level - electrically isolated
Insulation resistance EN 61131-2 -
Insulation voltage to reference earth
Inputs / outputs - AC / DC 50V,
test voltage AC 500V
Protective measures - against short circuit
Environmental conditions to EN 61131-2
Climatic
Storage / transport EN 60068-2-14 -25…+70°C
Operation
Horizontal installation EN 61131-2 0…+60°C
Vertical installation EN 61131-2 0…+60°C
Air humidity EN 60068-2-30 RH1
(without condensation, rel. humidity 10 … 95%)
Pollution EN 61131-2 Degree of pollution 2
Mechanical
Oscillation EN 60068-2-6 1G
Shock EN 60068-2-27 15G
Mounting conditions
Mounting place - In the control cabinet
Mounting position - Horizontal and vertical
EMC Standard Comment
Emitted
interference
EN 61000-6-4 Class A (Industry area)
Industry area
EN 61000-4-2 ESD
Degree of severity 3, i.e. 8kV at air discharge,
4kV at contact discharge
EN 61000-4-3 HF irradiation (casing)
80MHz … 1000MHz, 10V/m 80% AM (1kHz)
EN 61000-4-6 HF conducted
150kHz … 80MHz, 10V/m
80% AM (1kHz)
EN 61000-4-4 Burst, degree of severity 3
Noise immunity
zone B
EN 61000-6-2
EN 61000-4-5 Surge, degree of severity 3 *
)
*
)
Due to the high-energetic single pulses with Surge an appropriate external protective circuit with
lightning protection elements like conductors for lightning and overvoltage is necessary.