SECTION I INSTALLATION
17
1.5.4 EXHAUST GAS PROBE WIRING
Utilizing the
yellow
and red color coded thermocouple
extension wire
\---,
and terminals
(contained
in kit 3010002 / 3),
connect
probes
at the
DPU J2 connector as follows:
***
CAUTION*** Always discharge
yourself
to
ground
before wiring.
NOTE: Probe shorter lead is
YELLOW, and longer
RED.
J-'..--,,
NOTE:
For4
cyl engines,
jumper
J2-9to J2-1 0
and J2-11 lo J2-12.
5010002 Rf,v F
VMIOOO
OWNERS
MANUAL
DPU
TERM.
CABLE
COLOR
XDUCER
WIRE
XDUCER
DESCR.
XDUCER
PART
NO.
J2-1 YEL
YEL
EGT
1 PROBE
1
020060
J2-2 RED
RED
3t $
J2-3 YEL
YEL EGT 2
PROBE
1 020060
J2-4 RED
RED
J2-5
YEL
YEL
EGT 3 PROBE 1 020060
J2-6
RED RED
$
J2-7
YEL YEL
EGT 4 PROBE
1 020060
J2-8
RED RED
aa
J2-9 YEL
YEL
EGT
5
PROBE
1
020060
J2-10 RED RED
at
J2-11
YEL
YEL
EGT 6 PROBE
1
020060
J2-12
RED
RED
al