Quick Start Guide 
 
1. PROGRAMMING REGULAR PHONE NUMBERS 
The dialer can call up to 4 regular phone numbers per 
zone. To program the numbers to be called when zone 1 
(Z1) is in alarm: 
• Press 
 
- this selects location 1. 
• After the dial LED flashes twice, enter phone number to 
dial. 
•  Finish by pressing 
. 
Example: 
 
- this would dial phone 
number  555-1212 and deliver the message programmed for 
zone 1. 
 
Program the remaining phone numbers (2, 3 and 4) as above. 
For example: 
• Press 
 
- this selects location 2. 
• After the dial LED flashes twice, enter phone number to 
dial. 
•  Finish by pressing 
. 
Program numbers for zone 2 (Z2) in the same manner, 
except that the location numbers will be 5, 6, 7, & 8. Start with 
pressing 
 
 - this selects location 5.  
 
2. PROGRAMMING NUMERIC PAGERS 
Pagers require two phone number locations. Therefore, 
each DL-125C / DL-125CA zone can call a maximum of two 
pagers.  Proceed as follows to program pagers into zone 1: 
• Press 
 
 - this selects location 1. 
•  After the dial LED flashes twice, enter the phone number of 
the numeric pager. 
• Press 
 
- this links the current location with the next for 
pager function. 
• Press 
. 
• Press 
 
- this selects location 2. 
•  After the dial led flashes twice, press 
 
- this links this 
location to the previous location for pager function. 
• Press 
 
to provide a 10-second delay allowing the 
paging company to pick up (you can enter any two digit 
value, but 10 seconds works in most cases). 
•  Enter the number you wish to appear on the pager’s display 
and finish by pressing  
. 
Example: 
 
and then: 
 - this would deliver 
the message “9999” to a pager at phone No. 555-2525. 
If you wish to program another pager in zone 1, follow these 
same steps, but use locations 3 and 4. To program pagers 
into zone 2, use locations 5 & 6 and/or locations 7 & 8. 
 
3. RECORDING VOICE MESSAGES 
The DL-125C / DL-125CA contains three locations for voice 
messages.  The total recording time can not exceed 19 seconds. 
Location / common message (up to 14.5 sec.) - name and 
address that is common to AL-1 and AL-2 messages. 
Message AL-1 (up to 2.5 sec.) is the alarm type message for 
zone 1 (burglar alarm activation, for example). 
Message AL-2 (up to 2 sec.) is the alarm type message for 
zone 2 (low temperature detection, for example). 
You must record at least
 the common message and one of 
the alarm messages (AL-1 or AL-2). You cannot record only a 
common message. Recording should be done in the following 
order: 
To record AL-1 & AL-2 (location message): 
• Press   
•  Press and hold both 
 and 
 
buttons at the same time 
while reading the message aloud - red LED will be on. 
• Release 
 
and 
 
and press 
 - red LED will turn off. 
To record AL-1 message: 
• Press   
•  Press and hold
 
 while reading the message aloud - red 
LED will be on. 
• Release 
 
and press 
 - red LED will turn off. 
To record AL-2 message: 
• Press   
•  Press and hold   while reading the message aloud - red 
LED will be on. 
• Release 
 
and press 
 - red LED will turn off. 
 
 
For more advanced applications, refer to the DL-125C installation instructions, or contact the technical support. 
 
VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788 
VISONIC INC. (U.S.A.): ): 
65 WEST DUDLEY TOWN ROAD, BLOOMFIELD CT. 06002-1376. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094 
VISONIC LTD. (UK): FRASER ROAD, PRIORY BUSINESS PARK, BEDFORD MK44 3WH. PHONE: (0870) 7300800 FAX: (0870) 7300801 
INTERNET: www.visonic.com 
©VISONIC LTD. 2008    DL-125C, DL-125CA   DE5803Q (REV. 1, 10/08)