Quick Start Guide
1. PROGRAMMING REGULAR PHONE NUMBERS
The dialer can call up to 4 regular phone numbers per
zone. To program the numbers to be called when zone 1
(Z1) is in alarm:
• Press
- this selects location 1.
• After the dial LED flashes twice, enter phone number to
dial.
• Finish by pressing
.
Example:
- this would dial phone
number 555-1212 and deliver the message programmed for
zone 1.
Program the remaining phone numbers (2, 3 and 4) as above.
For example:
• Press
- this selects location 2.
• After the dial LED flashes twice, enter phone number to
dial.
• Finish by pressing
.
Program numbers for zone 2 (Z2) in the same manner,
except that the location numbers will be 5, 6, 7, & 8. Start with
pressing
- this selects location 5.
2. PROGRAMMING NUMERIC PAGERS
Pagers require two phone number locations. Therefore,
each DL-125C / DL-125CA zone can call a maximum of two
pagers. Proceed as follows to program pagers into zone 1:
• Press
- this selects location 1.
• After the dial LED flashes twice, enter the phone number of
the numeric pager.
• Press
- this links the current location with the next for
pager function.
• Press
.
• Press
- this selects location 2.
• After the dial led flashes twice, press
- this links this
location to the previous location for pager function.
• Press
to provide a 10-second delay allowing the
paging company to pick up (you can enter any two digit
value, but 10 seconds works in most cases).
• Enter the number you wish to appear on the pager’s display
and finish by pressing
.
Example:
and then:
- this would deliver
the message “9999” to a pager at phone No. 555-2525.
If you wish to program another pager in zone 1, follow these
same steps, but use locations 3 and 4. To program pagers
into zone 2, use locations 5 & 6 and/or locations 7 & 8.
3. RECORDING VOICE MESSAGES
The DL-125C / DL-125CA contains three locations for voice
messages. The total recording time can not exceed 19 seconds.
Location / common message (up to 14.5 sec.) - name and
address that is common to AL-1 and AL-2 messages.
Message AL-1 (up to 2.5 sec.) is the alarm type message for
zone 1 (burglar alarm activation, for example).
Message AL-2 (up to 2 sec.) is the alarm type message for
zone 2 (low temperature detection, for example).
You must record at least
the common message and one of
the alarm messages (AL-1 or AL-2). You cannot record only a
common message. Recording should be done in the following
order:
To record AL-1 & AL-2 (location message):
• Press
• Press and hold both
and
buttons at the same time
while reading the message aloud - red LED will be on.
• Release
and
and press
- red LED will turn off.
To record AL-1 message:
• Press
• Press and hold
while reading the message aloud - red
LED will be on.
• Release
and press
- red LED will turn off.
To record AL-2 message:
• Press
• Press and hold while reading the message aloud - red
LED will be on.
• Release
and press
- red LED will turn off.
For more advanced applications, refer to the DL-125C installation instructions, or contact the technical support.
VISONIC LTD. (ISRAEL): P.O.B 22020 TEL-AVIV 61220 ISRAEL. PHONE: (972-3) 645-6789, FAX: (972-3) 645-6788
VISONIC INC. (U.S.A.): ):
65 WEST DUDLEY TOWN ROAD, BLOOMFIELD CT. 06002-1376. PHONE: (860) 243-0833, (800) 223-0020 FAX: (860) 242-8094
VISONIC LTD. (UK): FRASER ROAD, PRIORY BUSINESS PARK, BEDFORD MK44 3WH. PHONE: (0870) 7300800 FAX: (0870) 7300801
INTERNET: www.visonic.com
©VISONIC LTD. 2008 DL-125C, DL-125CA DE5803Q (REV. 1, 10/08)