4 D-302894 SMD-426 PG2, SMD-427 PG2 Installation Instructions
B
C
D
A
A. 3 volts CR17450
B. Battery cover
C. Enroll button
D. Tamper switch
E. Open battery cover and connect the battery to its terminals.
Caution! Risk of explosion if battery is replaced by an incorrect type.
Dispose of used batteries according to the manufacturer's instructions.
Figure 9b. Battery Connection for CR17450
Note: When the battery first makes contact, the alarm horn may sound
for one second. This indicates that the battery is connected properly.
Close the cover, then place the detector on the holder and press the
test button (see fig. 1) for about 2 seconds, (for further details see
par. 3 "Smoke Detector Test").
E
2.6 Resetting the Transceiver Module
Closing the tamper switch initiates reset of the transceiver.
2.7 Enrollment
Refer to the PowerMaster panel's Installer Guide and follow the procedure under the "02:ZONES/DEVICES" option of the Installer Menu.
A general description of the procedure is provided in the following flow chart.
Step 1 Step 2 Step 3 Step 4 Step 5 Step 6
Enter the Installer menu
and select
“02:ZONES/DEVICES”
Select "ADD NEW
DEVICE" Option
See Note [1]
Enroll the device or Enter
the device ID
Select the desired Zone
Number
Configure the
Location Parameter
Configure
the
Smoke
Detector
See Note
[2]
means scroll and select
Notes:
[1] If the smoke detector is already enrolled you can configure the smoke detector parameters via the “Modify Devices” option – see Step 2.
[2] Select the "Device Settings" option and refer to section 2.8 to configure the smoke detector parameters.
2.8 Configuring the Smoke Detector Parameters
Enter the menu and follow the configuration instructions for the SMD-426 PG2 (smoke detector) and SMD-427 PG2 (heat
and smoke detector) as described in the following table.
Option Configuration Instructions
Here you determine whether or not the detector will activate a burglary alarm.
Options: ON and OFF (default).
Here you determine whether or not the detector will activate a fire alarm.
Options: ON and OFF (default).
Here you determine whether or not the detector will activate a gas alarm.
Options: ON and OFF (default).
Here you determine whether or not the detector will activate a flood alarm.
Options: ON and OFF (default).
Z11.DEV SETTINGS
Flood Siren
Gas / CO Siren
Fire Siren
Burglary Siren
DEV SETTINGS
Z11.LOCATION
ID No. 200-XXXX
Z11:Smoke Sens
ENTR ID:XXX-XXXX
ENROLL NOW or
MODIFY DEVICES
ADD NEW DEVICES
02.ZONES/DEVICES