153
Cable and Pipeline Fault Locating
• As the fault is neared, the arrow on the locator display will point forward and the
dB reading increase
• As the fault is passed the arrow will flip to point in reverse. When the spikes of
the A-frame are exactly straddled the fault, the dB reading will drop dramatically
and the arrows will either, both be on, or will flip forwards and backwards.
Fault Locating