A typical distorted field
Distorted Fields
The magnetic field (the signal) radiating from buried lines can be
distorted by the presence of adjacent metallic conductors or other
signals.
This is caused by:
Signals induced from the target line to other lines
Commonly bonded structures
Badly positioned ground (at the transmitter)
The result is that the locator detects signals from more than one source