- 56 -
C145301000.fm
English
Information about failures
GB
D700/750 E2-E3
Output reduction
Clogged fuel filter Replace filter (See “Fuel filter replacement”)
Presence of air in the fuel supply circuit
Carry out bleeding (See “Fuel supply circuit
bleeding”)
Injection pump malfunction
Replace the pump.
Apply to an authorised workshop
Dirty or faulty injectors
Replace the injectors.
Apply to an authorised workshop
Clogged air filter Clean or replace the filter
Engine overheating Apply to an authorised workshop
Insufficient combustion air flow Apply to an authorised workshop
The battery war-
ning light comes
on
The alternating current generator does
not charge the battery
Check and, if appropriate, replace the alter-
nating current generator.
Apply to an authorised workshop
The oil pressure
warning light co-
mes on
Engine oil pressure too low Apply to an authorised workshop
Problem Cause Remedy