Error Codes
The following are common error codes and solutions.
Error Code
Error
Solution
Error 1
Motor phase wire fault
Check motor phase wires from the motor axle all the
way to the controller. Check that there are no exposed,
loose or damaged connections or cabling.
Error 2
Motor hall sensor fault
Check motor hall sensor wires from the motor axle all
the way to the controller. Check that there are no
exposed, loose or damaged connections or cabling.
Error 3
Throttle fault
Check the throttle cable for a loose connection or
damage and see if the error goes away. If not, the
sensor box may be faulty and need replacement.
Error 4
Under voltage fault
Check the battery voltage and the system settings to
ensure they are set correctly. If it is below working
voltage range, you may receive this error.
Error 5
Controller fault
Check the display to determine which controller is
faulty. Will likely require replacement.
Error 6
Instrument fault
Check if the TFT display, button console, cables and
connections are not damaged and seated correctly.
Error 7
Over temperature fault
Immediately stop using the scooter and let it cool for
awhile until the error subsides. This is a temperature
over-protection feature to ensure the scooter doesn’t
get too hot.
Distributed by and property of VoroMotors 12