Details manufacturer's responsibility and warranty conditions for the instrument.
Specifies the authorized uses and purpose of the PCD-06.
Defines misuse of the instrument and potential consequences.
Outlines the necessary qualifications for operating personnel.
Provides essential safety guidelines for all installation, operation, maintenance, and repair work.
Emphasizes keeping operational manuals and safety documentation accessible.
Stresses the importance of using genuine parts for operational safety and warranty claims.
Explains the meaning of various symbols and notices used in the operation manual.
Provides instructions for safe handling and transport of the instrument.
Explains the principles of particle charge measurement and electrokinetic effects.
Details the measuring principle and sample handling within the measuring cell.
Explains the methods for calculating charge density and demand from titration data.
Describes how to identify the isoelectric point (IEP) using acid/base titration.
Presents and explains different types of titration curves generated by the instrument.
Shows and explains titration curves specific to colloidally dissolved particles.
Shows and explains titration curves for samples containing solid particles.
Shows and explains titration curves for heterogeneous systems.
Lists various industries and applications where the PCD-06 is utilized.
Identifies the instrument's type plate and service sticker for designation.
Details the information presented on the device's rear panel type plate.
Explains the purpose and content of the instrument's service sticker.
Lists key specifications of the Mütek™ PCD-06, including dimensions and limits.
Declares conformity of the instrument with relevant EU directives and standards.
Lists all standard and optional items included in the product package.
Details the components included in the standard delivery of the instrument.
Provides a front view of the PCD-06, highlighting its main components.
Describes the precision measuring cell and displacement piston.
Explains the optional pH electrode and its use for isoelectric point determination.
Details the various connections and controls located on the rear of the instrument.
Lists essential safety precautions to be followed during installation and commissioning.
Specifies that only qualified and skilled personnel should perform installation.
Outlines necessary preparations and ambient conditions before instrument installation.
Defines the suitable environmental conditions for installing the instrument.
Provides requirements for the physical location and setup of the PCD-06.
Details power connection requirements, voltage checks, and earthed socket usage.
Provides guidelines on sample properties like particle size, viscosity, and molecular weight.
Lists and describes essential solutions including titrants, acids, bases, and cleaning agents.
Explains the selection, type, and usage of titrants for the instrument.
Describes the use of diluted acids and bases as titrants for specific sample types.
Details the composition and recommended procedure for the cleaning solution.
Guides through the initial steps to start and prepare the instrument for operation.
Specific start-up steps applicable to the Standard and Premium PCD-06 models.
Instructions for connecting the PCD-06 Light model with an external automatic titrator.
Provides a step-by-step guide for changing the titrant bottle in the instrument.
Details the procedure for rinsing the instrument's dosing tubes and system.
Refers to basic safety instructions that must be followed before operating the instrument.
States that only qualified and skilled personnel are permitted to operate the Mütek™ PCD-06.
Displays and explains the main interface screens for instrument operation.
Guides on different methods for preparing samples for accurate charge measurements.
Discusses filtration methods, advising against paper filters due to potential adsorption.
Mentions the importance of maintaining identical centrifugation periods for all samples.
Explains the process of screening samples using a nylon screen to remove larger particles.
Describes the back titration method suitable for specific sample types and conditions.
Provides a practical example with calculations for performing back titration.
Provides instructions on how to correctly fill the measuring cell with the sample.
Details the measurement process specific to the PCD-06 Light model.
Explains the procedure for performing manual titration on the instrument.
Outlines the steps to initiate a measurement process on the PCD-06.
Describes the steps to perform the titration part of the measurement.
Instructions for operating the PCD-06 in conjunction with an external automatic titrator.
Steps to start a measurement when using an external titrator.
Steps to start titration when using an external titrator.
Details the measurement process for the Standard and Premium PCD-06 models.
Steps to initiate a measurement on the Standard or Premium PCD-06.
Explains how to manage, view, and interpret measurement results stored in memory.
Guides on transferring measurement data from the instrument to a USB storage device.
Details how to export instrument settings and parameters to a USB stick.
Covers the adjustment and usage of different pre-set and custom titration methods.
Describes the configuration and parameters of the instrument's standard titration methods.
Covers method name, description, settling time, type, and termination settings.
Explains how to program the titrant volume for each dosing step (Fixed/Dynamic).
Accesses device settings including About Device, Titrant Settings, and pH Calibration.
Displays information about the instrument, including software version and service dates.
Allows configuration of titrant parameters like name, type, normality, and expiry date.
Guides on calibrating the pH electrode using buffer solutions for accurate measurements.
Instructions for setting and adjusting the device's current date and time.
Covers calibration procedures for pumps, analog inputs, and output signals.
Explains how to adjust the output signal for compatibility with external titrators.
General safety advice to be followed before performing any troubleshooting procedures.
States that troubleshooting activities must only be performed by qualified and skilled personnel.
Lists common malfunctions with causes and recommended corrective actions.
Details specific error messages displayed by the PCD-06 Smart and their solutions.
Lists common operational faults experienced with the instrument and their solutions.
Provides instructions for cleaning the instrument's outer surfaces and internal measuring cell.
How to clean the outer surfaces of the Mütek™ PCD-06 device.
Specific cleaning procedure for the instrument's measuring cell and displacement piston.
General guidelines and requirements for performing maintenance on the instrument.
States that all maintenance tasks must be performed by qualified and skilled personnel.
Describes various methods for performing functional tests to ensure instrument accuracy.
Procedure for a basic functional test without the measuring cell installed.
Explains the procedure for performing a standard titration for verification.
How to check the stability and expected range of the streaming potential measurement.
Procedure to test for electrostatic charging issues affecting the measuring cell signal.
How to perform functional tests on the pH electrode for proper operation.
Guidelines for correctly storing, handling, and maintaining the pH electrode.
Information about the BTG maintenance program for annual instrument inspection.
Safety rules that must be adhered to when shutting down the system.
States that system shutdown must be performed by qualified and skilled personnel.
Step-by-step procedure for powering down the instrument and disconnecting it.
Guidelines for storing the Mütek™ PCD-06 in a suitable and protected environment.
Information regarding the proper disposal of the instrument.
Notes the requirement to comply with current local regulations for instrument disposal.
Lists all available spare parts for the Mütek™ PCD-06 with their corresponding part numbers.
Lists optional accessories that can be purchased for the instrument.
Lists consumable items such as titrants, buffer solutions, and cleaning solutions.