P
r
o
t
e
c
t
e
d
b
y
c
o
p
y
r
i
g
h
t
.
C
o
p
y
i
n
g
f
o
r
p
r
i
v
a
t
e
o
r
c
o
m
m
e
r
c
i
a
l
p
u
r
p
o
s
e
s
,
i
n
p
a
r
t
o
r
i
n
w
h
o
l
e
,
i
s
n
o
t
p
e
r
m
i
t
t
e
d
u
n
l
e
s
s
a
u
t
h
o
r
i
s
e
d
b
y
V
o
l
k
s
w
a
g
e
n
A
G
.
V
o
l
k
s
w
a
g
e
n
A
G
d
o
e
s
n
o
t
g
u
a
r
a
n
t
e
e
o
r
a
c
c
e
p
t
a
n
y
l
i
a
b
i
l
i
t
y
w
i
t
h
r
e
s
p
e
c
t
t
o
t
h
e
c
o
r
r
e
c
t
n
e
s
s
o
f
i
n
f
o
r
m
a
t
i
o
n
i
n
t
h
i
s
d
o
c
u
m
e
n
t
.
C
o
p
y
r
i
g
h
t
b
y
V
o
l
k
s
w
a
g
e
n
A
G
.
DANGER!
Hazardous voltage resulting from damaged high-voltage com‐
ponents
Observe the following when working in the vicinity of high-volt‐
age components and cables:
♦ Work involving metal-removing, deforming and sharp-
edged tools or heat sources such as welding, soldering,
hot air and thermal bonding is not permitted.
♦ Before starting work, carry out a visual check on the high-
voltage components in the area of work.
♦ When working in the engine compartment, carry out a vis‐
ual check on the power and control electronics for electric
drive - JX1- , the electric drive motor - V141- , the air con‐
ditioner compressor - V470- and the high-voltage cables.
♦ When working on the underbody, carry out a visual check
on the high-voltage cables and covers.
♦ When working on the rear end, carry out a visual check on
the high-voltage cables and the maintenance connector
for high-voltage system - TW - .
♦ Carry out a visual check on all potential equalisation lines.
When carrying out the visual check, observe the following:
♦ The high-voltage components must not reveal any exter‐
nal damage.
♦ The insulation of the high-voltage cables and the potential
equalisation lines must not be damaged.
♦ The high-voltage cables must not show any unusual de‐
formations.
♦ Each high-voltage component must be clearly identified
with a red warning sticker.
If repair work in the vicinity of high-voltage components and ca‐
bles is necessary, “carry out a visual check for damage on high-
voltage components and cables”, and “observe the general
warning instructions for work on the high-voltage system” ⇒ Elec‐
trical system; Rep. gr. 93 ; General warning instructions for work
on the high-voltage system .
If repair work on high-voltage components is necessary, de-en‐
ergise the high-voltage system ⇒ Electrical system; Rep. gr. 93 ;
De-energising high-voltage system , and “observe the general
warning instructions for work on the high-voltage system” ⇒ Elec‐
trical system; Rep. gr. 93 ; General warning instructions for work
on the high-voltage system .
Amarok 2011 ➤ , Beetle 2012 ➤ , Bora 1999 ➤ , CC 2010 ➤ , CC 2012 ➤ , ...
Air conditioning system with refrigerant R134a - Edition 10.2014
68 Rep. gr.00 - Technical data