VOLTECH AT3600 USER MANUAL PROGRAMMING TESTS
TEST PROGRAM EDITOR VPN 98 - 024 PAGE 3.4.47.
4.28 WATT - WATTAGE
The Wattage test is a measure of the input power required to energize a transformer at
no load.
During the test, a constant, user specified ac voltage is applied across the winding in
question; the power is then measured. All other windings are held open circuit during
this test.
On selecting the WATT test the following dialogue box will be displayed:
To program the test :
1. Enter the test voltage and frequency.
2. Select which are to be the high & low terminals.
For each terminal; click with the mouse cursor positioned over the desired
terminal name.
3. Enter the maximum wattage value in the bottom section.
4. Select OK. The test specification will then be displayed in the program window.
Note: The measure button may be used as outlined in section 3.9 to ‘Auto-Specify’
the wattage test parameters.