EXECUTE MODE VOLTECH AT3600 USER MANUAL
PAGE 6.3.14. VPN 98 - 024 FRONT PANEL OPERATION
After pressing the CONTINUE soft-key, the remaining tests in the program will be
executed, and at the end of the measurement, the component will be classed as a
‘Fail’.
Pressing the RE-RUN soft-key will re-start the test sequence from the beginning.
Note: After making the necessary adjustments, you must press RE-RUN to enable
the component to be recorded as a ‘Pass’.
If further adjustment is necessary, you may re-run from the start as many
times as you like. Unless the option ‘Send Retry Results to Server’ is
enabled, there will be no data sent back to the Server until the measurements
for all tests in the program have been completed.
As TRIM can only be applied to a test that uses a low voltage generator, the
safety interlocks will not be in operation while adjustments are being made.
All transformers are capable of generating voltages much higher than the test
voltage.
!
When making adjustments, take care not to touch any transformer terminals,
the transformer body, or any exposed metal on the test fixture. Ideally, make
sure that you use trimming tool with a well insulated handle.
When applying a test signal to a winding, always be mindful of the turns ratio of
the transformer you are testing. Very high voltages can be generated on the
other windings of the transformer, if these voltages exceed 7kV the tester may be
permanently damaged.