EasyManua.ls Logo

Voltech AT3600 - Page 339

Default Icon
424 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
VOLTECH AT3600 USER MANUAL TRANSFORMER TESTS
TESTS AND TEST CONDITIONS VPN 98 - 024 PAGE 7.1.59.
In practice, the magnetising current waveform may have a transient component
following the switch-on of the test voltage. To give you repeatable accurate results,
the measurement does not start until any transient has settled.
The test signal can have a frequency in the range 20Hz to 5KHz, and an amplitude
from 5V to 600V depending on the type of external source used. The current rating of
a single AC Source Interface is 10A rms. See also the MAGI test which uses the
AT3600s internal generator which can provide up to 270V ac at 40W.