SPECIFICATION VOLTECH AT3600 USER MANUAL
PAGE 8.1.12. VPN 98 - 024 SPECIFICATION
LVOC TEST
The accuracy for measuring open circuit voltage is given as:
VCRT
AAAA ++=
where
A
T
is the total accuracy (%)
A
R
is the basic relative accuracy (%)
A
C
is the calibration accuracy (%)
A
V
is the correction for voltage level (%)
The value of A
R
is given in the section 1.1 of this chapter.
The values of the other factors are given below.
MC
FA ×+= %001.0%03.0
MV
VA %001.0%03.0 +=
where
F
M
is the measurement frequency (Hz)
V
M
is the measured voltage (V)