SPECIFICATION VOLTECH AT3600 USER MANUAL
PAGE 8.1.32. VPN 98 - 024 SPECIFICATION
DCVB TEST
The accuracy for the test voltage is given by:
The accuracy for the test current is given by:
RNGICVRT
AAAAAA
+=
where
A
T
is the total accuracy (%)
A
C
is the calibration accuracy (%)
A
I
is the correction for current level (%)
%/10%3
MV
VA +=
%03.0
=
C
A
MI
IA %00006.0=
%
MRNG
VRangeA =
where
I
M
is the maximum test current (A)
V
M
is the actual voltage (V)
Range is the voltage range used for the measurement that will be the lowest
possible of the following ranges:
333V
1000V
3000V
10000V
The value of A
R
is given in the table in section 1.1. of this chapter.
(V ) = 3%
TEST