VOLTECH AT3600 USER MANUAL SAFETY SYSTEMS
SAFETY SYSTEMS VPN 98 - 024 PAGE 10.9.
The following show plan and side views of a typical installation:
The dimensions are as follows:
a. Width of the light curtain: 1.8m to 2.0m
b. Cable length from control box
to vertical columns: 2m
c. Cable length from control box
to tester: 1.5m
d. Lowest beam in light curtain: 60mm
maximum above the work surface
e. Highest beam in light curtain: 630mm
minimum above the work surface
f. Maximum object resolution: 18mm