RX/RX-LC/S1!Switch!Retrofit!Kit
Base!Plate
Assembly
➂ Remove!push!bar.
Slide
to
remove
Slide
to
remove
➀!Remove!screws.
➁ Remove!mechanism!case.
Dogging!assembly!may!not
be!present!on!all!devices.
Step! ➊
Disassemble!the!device.!(Remove!from!door!if!mounted.)
!This!kit!includes!the!following!parts:
8-18!X!3/8"!Flat!Head!Screw!(2)
Switch!Assembly
Nylon!Fastener
This!switch!is!intended!for!signaling!purposes!only!and!is!rated!for!a
.1!ampere!to!3!ampere!resistive!load!at!24VDC/AC.!Use!with!inductive
or!capacitive!loads!(magnetic!locks!or!solenoid!devices)!derates!the
capacity!of!the!switch.!Consult!the!factory!for!assistance.
22!Device
Cable Tie 1.5"
INSTALLATION INSTRUCTIONS
RX
{
This!switch!is!intended!for!systems!using!low!current!signals.!The!switch!is
rated!for!a!maximum!of!50mA.!Consult!the!factory!for!assistance.
RX-LC
{
Standard (RX)
or low current (RX-LC)
941038_00(4) Copyright © 2003 Ingersoll-Rand. All rights reserved.
VON DUPRIN
®