Summary

Introduction

Operating instructions

General

Describes display and function key operation for AST 3P in normal Operating mode.

Power supply

Details power supply requirements and recommendations for continuous operation.

Start-up

Explains the instrument's start-up sequence and initial display in Operating mode.

View alternatives

Weight value, normal view

Displays the actual measurement value, instrument address, and relay status.

Zero setting

Shows weight value, address, and 'Zero' key for temporary zeroing.

Analogue output

Displays weight value, address, and the actual analogue output signal.

Level settings

Shows switching levels for supervising channels or level 0 if not used.

Input signal

Displays the actual input signal from the transducer and relay status.

S/N:, Progr.

Displays the instrument serial number and installed programme name.

Zero setting

Procedure

Step-by-step guide for performing a zero setting in set-up mode to save to memory.

Installation

Mechanical installation

Describes how to mount the module on a DIN rail or flat surface.

Electrical installation

Details requirements for connecting cables, avoiding interference, and routing.

Transducer input

Explains transducer connection, handling, and notes on cable routing and termination.

Power supply

Analogue output

Serial communication

Set-up programme deltaCOM

Quick set-up, calibration

General

Overview of parameter setup via deltaCOM or panel, and calibration methods.

Common parameters

Defines language, measurement unit, resolution, capacity, and signal type parameters.

Set-up

Instructions on how to access the 'Quick set-up' menu from normal operation mode.

Showing the parameters

Explains how to initiate parameter display in 'Quick set-up'.

Edit the language

Guides on selecting and confirming the language setting.

Edit the measurement unit

Describes how to define the measurement unit for the instrument.

Edit the instrument resolution

Explains how to set the number of decimals and resolution of the last digit.

Edit the instrument capacity

Guides on setting the instrument capacity corresponding to full analogue output range.

Edit the analogue output type

Defines the signal type for the analogue output.

Chose a calibration type

Explains how to select between Data sheet and Deadweight calibration types.

Data sheet calibration

Edit the conversion factor

Sets a constant to convert weight to data sheet unit.

Edit the number of transducers

Defines the total number of support points for the load.

Set the rated load for one transducer

Enters the rated load for a transducer as per data sheet.

Set the rated output for the transducers

Sets the rated output (mV/V) for each transducer or fixed support.

Set the scale to zero

Sets the weight value to zero for the unloaded scale.

Read the zero offset

Reads the total zero offset value for scale setup.

Exit 'Quick set-up'

Exits the 'Quick set-up' menu to the main menu.

Save the changes

Explains how to save or cancel changes made during 'Quick set-up'.

Dead weight calibration

Set the value for calibration point 1

Defines the known load for the lower calibration point.

Set the value for calibration point 2

Defines the known load for the higher calibration point.

Read the transducer signal for calibration point 1 (read only)

Reads the transducer signal value for calibration point 1.

Read the transducer signal for calibration point 2 (read only)

Reads the transducer signal value for calibration point 2.

Set the scale to zero

Sets the weight value to zero for the unloaded scale.

Read the zero offset

Reads the total zero offset value for scale setup.

Exit 'Quick set-up'

Exits the 'Quick set-up' menu to the main menu.

Save the changes

Explains how to save or cancel changes made during 'Quick set-up'.

Parameter survey

Quick set-up list for AST 3