Do you have a question about the vse VSI 0.04 and is the answer not in the manual?
Brand | vse |
---|---|
Model | VSI 0.04 |
Category | Measuring Instruments |
Language | English |
Information regarding the document's management, updates, and liability limitations.
Follow all instructions for trouble-free operation; VSE is not liable for damage from non-compliance.
Crucial for trouble-free and safe operation; consult VSE for exact descriptions.
Flow meters tested for electromagnetic compatibility and EMC directives; CE-certification confirmed.
Checks fluid properties, cleanliness, compatibility with seals, and system deaeration.
Checks fluid properties, cleanliness, compatibility with seals, and system deaeration.
Checks system pressure, pressure fall, flow range, temperature, pipe size, and connections.
Checks preamplifier, power supply, electric connection, cable shielding, and EMC compliance.
Ensures system pressure does not exceed the flow meter's maximum permitted operating pressure.
VSE flow meters are pressurized devices subject to EU Directive 97/23/EG, but do not require CE-marking.
Direct mounting onto a subplate or manifold using four screws; ensure proper torque.
Dimensional drawing and specifications for APG 10 SGON/1 subplate.
Dimensional drawing and specifications for APG 10 SWON/1 subplate.
Details input capabilities for quadrature and single-channel signals, HTL/TTL levels, and differential formats.
Shows how to connect TTL encoders, including differential operation without GND connection.
Illustrates connecting HTL encoders, which can be supplied from the converter or another source.
Describes connections for single-channel operation, frequency combinations, and 2-wire NAMUR sensors.
Details the +/-10V voltage output and 0-20mA/4-20mA current output capabilities.
Explains RS232 and RS485 interface options for PC communication and parameter setting.
Sets operation modes like Channel A/B only, Quadrature, Sum, Difference, or Product.
Sets input combinations for levels (HTL/TTL) and formats (symmetric/asymmetric, differential).
Provides three standard settings for common encoders/sensors with uniform input levels.
Offers detailed settings for various input levels and characteristics for special applications.
Sets the desired analogue output format (Voltage or Current) via DIL switch positions.
Selects between RS232 and RS485 serial interfaces using DIL1 switch position 1.
Configures Teach/Test modes and loading of factory default parameters via DIL1 switch.
Guides setting minimum and maximum frequencies for analogue output scaling using the Teach function.
Teaches minimum/maximum frequencies for channels A and B separately before combining them.