17
EPG S2
OPERATING MANUAL
VERSION 09/2017 ORDER NUMBER DOC2317574
Exhaust air containing oil!
Risk of poisoning if inhaled.
Provide compressed air free from oil and water
(Quality Standard 3.5.2 according to ISO 8573.1)
3.5.2 = 5 μm / +7 °C; +44.6 °F / 0.1 mg/m³.
WARNING
NOTICE
Compressed air quality, accessories
Danger of damage to the device.
Operate the control unit only with the prescribed compressed air quality.
Only use the control unit with original WAGNER accessories.
Non-observance of these conditions results in the warranty expiring!
Ambient conditions:
If low-melting powders are used, the ambient temperature may have to be lower than +30 °C;
+86 °F.
Volume measures:
for volumes speci ed in Nm³ (standard cubic meters). One cubic meter of a gas at 0 °C and
1.013 bar is called norm cubic meter.