5.5 DISPLAY AND OPERATING ELEMENTS
5.5.1 DISPLAY ELEMENTS, FRONT SIDE
1 LED display: "Operating voltage"
– The LED lights up green when the operating voltage is activated
2 LED display: "CAN Data Communication"
– The LED lights up green during data communication with the master
3 LED display: "Release"
– The LED lights up green when enabling has taken place
4 LED display: "Air"
– The LED lights up green when the air module is activated
5 LED display: "High voltage"
– The LED lights up green when the high voltage is activated
6 LED display: "Warning/Malfunction"
– The LED ashes in the event of a warning and lights up red in the event of a malfunction
Displays 4 - 6 exist for both gun A and gun B.