39
EPG S2
P_01505
4 5 63126 5 4
OPERATING MANUAL
VERSION 09/2017 ORDER NUMBER DOC2317574
7.6 DIAGNOSIS AND MONITORING
7.6.1 LED DISPLAYS
9 colored LEDs show various states, activities and malfunctions.
1 LED Power
Lights up green as soon as the device is switched on
2 LED CAN
Lights up green during the data communication with the master controller
3 LED Release
Lights up green when the 24 V release is present
4 LED air ON (gun A/gun B)
Lights up green when the air controller works
5 LED high voltage ON (gun A/gun B)
Lights up green when high voltage is switched on
6 LED malfunction
Lights up red when an error has occurred