EPG-SPRINT.
OPERATING MANUAL
VERSION 08/2010
ORDER NUMBER DOC 2305222
Warning No. Warning Cause Rectifi cation
E02 Dosage air too low. Set set point cannot be
reached.
Causes:
Hose kinked / blocked.
Input air pressure too low.
Injector is not connected.
System cannot reach target
setting.
Check hoses and hose
laying.
Ensure that input pressure is
greater than 6 bar.
Connect injector.
Select smaller set point
value.
Example: feed air for
ED pump max. 3.5 Nm³/h.
E03 Feed air too low. Set set point cannot be
reached.
Causes:
Hose kinked / blocked.
Input air pressure too low.
Injector is not connected.
System cannot reach target
setting.
Check hoses and hose
laying.
Ensure that input pressure is
greater than 6 bar.
Connect injector.
Select smaller set point
value.
Example: feed air for
ED pump max. 3.5 Nm³/h.
E04 Fallen below Tribo
current limit for 10 s.
The Tribo current set in the
confi guration cannot be
reached.
Causes:
Tribo air set too low.
Powder not fl owing due to
incorrect settings for feed air
and total air.
No powder in container.
The powder does not have
the required charging
characteristics.
Increase Tribo air.
Correct feed air and total air
settings.
Fill powder container.
Use suitable powder.