31
8.2.5 CHANGING OR CLEANING FILTER INSERT
1. Flush and clean the spray gun in accordance
with Chapter 8.1.2.
B_03649
64
83
66
67
open
2. Relieve the pressure of the spray gun and
device.
3. Secure the spray gun with the trigger
locking device.
4. Loosen the lter housing (67) manually with
turning handle (66) and unscrew it. When the
product hose together with lter housing
and lter insert has been exposed, push the
turning handle (66) back onto the upper lter
connection.
5. Pull the lter insert (64) out of the lter
housing (67).
6. Thoroughly clean all parts with ushing
agent.
Assembly:
7. Push the cleaned or new lter insert (64) with
opening downwards into the lter housing
(67).
8. Insert the lter housing (67) into the turning
handle, screw in manually with the turning
handle and tighten.
Procedure if connection is dicult to loosen:
Loosen lter housing (67) with wrench size
B open-end wrench, supporting the lter
connection with size A open-end wrench.
Wrench A Wrench B
13 mm
0.51 inch
17 mm
0.67 inch
B_02387
A
Note:
Do not unscrew the
lter connection.
The lter connection
should be replaced
in accordance with
Chapter 10.9.
VERSION 06/2018
ORDER NUMBER DOC2311730