53
GM 4700AC
4
1
3
2
14(F)
13
36
33
B_02390
OPERATING MANUAL
VERSION 06/2014 ORDER NUMBER DOC2311730
1. Relieve pressure from the gun and from the device in accordance with
Chapter 7.3.3.
2. Clean and decommission in accordance with Chapter 8.1.3.
3. Secure the gun with the locking device.
4. Unscrew the union nut with nozzle guard (33).
5. Remove the air cap (36) together with the nozzle (13).
6. Remove the defective sealing ring (14/F) with the help of pipe tongs or with a large
screwdriver.
7. Assembly: attach the new distributor seal (14/F) to the air cap (36).
8. Place the air cap, together with sealing ring (14/F), into the gun body.
9. Attach the union nut (33) and screw it in until the sealing ring snaps into place in
the mounting groove (audible snap).
10. Demount the union nut (33) and air cap (36) and complete the spray gun according
to Chapter 7.3.4.
10.6 REPLACING THE "AIR" SEALING RING
NOTICE
Shaping air and atomizer air not separate!
Poor spray pattern
Spray jet cannot be adjusted.
Treat the distributor seal (F) with care.