12
Super Finish 33 PLUS/PRO • Nespray Pro
3.8 INDICATORS AT THE ELECTRIC CONSOLE
POS DESCRIPTION
1 LED red (Indicator for voltage supply - lights up when there is voltage supply)
2 LED green (Indicator for “ready for operation” – lights up when there is voltage supply and the thermal fuse is closed
= means temperature of the motor is ok)
3 LED yellow (Indicator for contactor – lights up when contactors are xed and there is voltage supply for the motor)
RED
GREEN YELLOW
3.9 SOFT START CONTROLLER UPGRADE SERVICE KIT 2404531
GB
1. Lift the board to loosen screw (1).
2. Mount the soft start circuit (2).
Attention: Place the toothed washer
(3) under the lower screw for earthing
(tightening torque 5 Nm).
3. Wiring (4) according to the following wiring
diagrams (the complete wiring diagrams can
be found in the „Electrical Repair Instructions“
at the end of this service manual).
1
2
4
3
If required, the soft start controller
not included in the standard con-
guration of the SF33 can be retrot-
ted by the service department.