EasyManua.ls Logo

WarmFlow Air Source AS03 - Page 7

Default Icon
76 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Page 5
Table 2 Product information
Model
AS03
Air-to-water heat pump
Yes
Water-to-water heat pump
No
Brine-to-water heat pump
No
Low-temperature heat pump
No
Equipped with a supplementary heater
No
Heat pump combination heater
No
Symbol
Value
Rated heat output
Prated
17
Declared Capacity of heating for part load at indoor temp. 20°C and outdoor temp., T
j
T
j
= -7°C
Pdh
9.8
T
j
= 2°C
Pdh
6.0
T
j
= 7°C
Pdh
6.2
T
j
= 12°C
Pdh
7.6
T
j
= bivalent temperature
Pdh
9.8
T
j
= operation limit temperature
Pdh
8.9
Bivalent temperature
Tbiv
-7
Cycling interval capacity for heating
Pcych
-
Degradation coefficient
Cdh
-
Seasonal Space Heating Energy Efficiency
ηs
128
T
j
= -C
COPd
1.89
T
j
= 2°C
COPd
3.15
T
j
= 7°C
COPd
4.47
T
j
= 12°C
COPd
6.90
T
j
= bivalent temperature
COPd
1.89
T
j
= operation limit temperature
COPd
1.58
Operation limit temperature
TOL
-10
Cycling interval capacity for heating
COPcyc
-
Heating water operating limit temperature
WTOL
55
Power consumption in modes other than active
Off mode
P
OFF
0.009
Thermostat-off mode
P
TO
0.000
Standby mode
P
SB
0.009
Crankcase heater mode
P
CK
0.000
Other items
Capacity control
Variable
Sound power level indoors
LWA
58
Annual energy consumption
QHE
6949
Rated air flow rate
-
7.6