30
QUICK REFERENCE GUIDE
MANUAL REGENERATION
NOTE: If you need to initiate a manual regeneration, either
immediately, or the same night at the pre-programmed time for
regeneration (typically 12:00 AM), complete the following steps.
For Immediate Regeneration:
Press and hold REGEN until valve motor starts (typically 3 seconds).
For Regeneration the same night:
Press and release REGEN (notice that flashing “REGEN TODAY” appears).
BYPASS VALVE OPERATION
To shut off water to the system, position arrow handles as shown in
the bypass operation diagram below. If your valve doesn’t look like
the diagram below, contact your service technician for instructions
on how to shut off water.
NORMAL OPERATION BYPASS OPERATION
GENERAL OPERATION
When the system is operating, one of four displays will be shown:
1. time of day/gpm
2. flow rate
3. capacity remaining
4. days to a regen
Pressing NEXT will toggle between the four choices.
DAYS TO A REGEN
GPM
3
8
CAPACITY REMAINING
GPM GAL
1600
8
FLOW RATE
GPM
8.0
TIME OF DAY MON
GPM
2:408
PM
TO SET TIME OF DAY
In the event of a prolonged power outage, time of day flashes,
indicating that this needs to be reset. All other information will be
stored in memory no matter how long the power outage.
1. Accessed by pressing
SET CLOCK
2. Adjust hours with + and buttons, AM/PM toggles at 12
3. Press NEXT
4. Adjust minutes with + and buttons
5. Press NEXT
6. Adjust current day with + and buttons
7. Press NEXT to complete and return to normal operation
CURRENT DAY
SET
MON
TIME MINUTES
SET
TIME HOUR
SET
2:00
AM
2:00
AM
ERROR
If the display toggles between “Error”
and an error code (i.e. a number), call
a service technician and report the
error code.
REGEN TODAY MON
GPM
2:408
PM
REGEN TODAY and TIME OF DAY
will ash alternately if a regeneration
is expected tonight.
ADJUST HARDNESS, DAYS
BETWEEN REGENERATION,
AND TIME OF REGENERATION
For initial set-up or to make adjustments,
please complete the following steps.
1. Accessed by pressing
NEXT and + button
simultaneously
2. Adjust hardness using + and buttons
3. Press NEXT
4. Adjust days between regenerations using
+ and buttons
5. Press NEXT
6. Adjust time of regeneration hour with +
and buttons, AM/PM toggles at 12.
7. Press NEXT
8. Adjust time of regeneration minutes with
+ and buttons
9. Press NEXT
10. Turn display backlight ON or OFF with
+ and buttons. Default is ON.
11. Press NEXT to complete and return to
normal operation.
DAYS BETWEEN REGEN
SET
12
REGEN TIME HOUR
AM
SET
2:00
WATER HARDNESS
GR
SET
20
REGEN TIME MINUTES
AM
SET
2:00
LIGHT NORMALLY
SET
ON
ERROR
106
CALL FOR SERVICE