EasyManua.ls Logo

Water Right Impression Series - System Connections; Brine Tank and Overflow Line Setup

Water Right Impression Series
32 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 7
INSTALLATION
9. SAFETY BRINE TANK CONNECTION: Install the 3/8” O.D. polyethylene tube from the Refill Elbow to the
Brine Safety Float valve in the brine tank.
10. OVERFLOW LINE CONNECTION: An overflow drain line is recommended where a brine overflow could
damage furnishings or the building structure. Your softener is equipped with a brine tank safety float which
greatly reduces the chance of an accidental brine overflow. In the event of a malfunction, however, an overflow
line connection will direct the “overflow” to the drain instead of spilling on the floor where it could cause
considerable damage. This fitting is an elbow on the side of the brine tank. Attach a length of 1/2” I.D. tubing
to fitting and run to drain. Do not elevate overflow line higher than 3” below bottom of overflow fitting. Do not
“tie” this tube into the drain line of the control valve. Overflow line must be a direct, separate line from overflow
fitting to drain, sewer, or tub. Allow an air gap as per the drain line instructions.
Connection at Refi ll Elbow on the control valve Connection at Brine Safety Float in brine tank