What to do if my Water Right Water Filtration System control valve does not regenerate automatically?
- AAmber RamosDec 1, 2025
If the control valve does not regenerate automatically but does when you depress and hold the correct button(s), consider the following: * The bypass valve may be in the bypass position: Turn the bypass handles to place the bypass in the service position. * The meter may not be connected to the meter connection on the PC board: Connect the meter to the three-pin connection labeled METER on the PC board. * The meter turbine may be restricted or stalled: Remove the meter and check for rotation or foreign material. * There may be incorrect programming: Check for programming errors. * The meter wire may not be installed securely into the three-pin connector: Verify that the meter cable wires are installed securely into the three-pin connector labeled METER. * The meter may be defe...