Softener/Filter Installer/User Screens
Accessed by pressing and holding NEXT and + simultaneously for three seconds.
Returns to general display after five minutes of inactivity.
Softeners
Filters
Set water hardness with + or — buttons
Adjustable from 1-150 grains, within limits determined by capacity settings
as to not override gallons capacity setting. Default setting is 20 grains.
NOTE: This screen will not display if the unit is set to “FILTERING” mode (see OEM FILTERING SECTION).
Set days between a regeneration with + or — buttons
Adjustable from 1-28 days, or OFF.
Default setting is 6.
Set hour of regen time with + or — buttons
If IMMEDIATE REGEN is set (see Service OEM page), regen will be
immediate once total capacity is exhausted and ON ZERO will be displayed.
Default setting is 2:00 AM.
Set minutes of regen time with + or — buttons
If IMMEDIATE REGEN is set (see Service OEM page), regen will be
immediate once total capacity is exhausted and ON ZERO will be displayed.
Default setting is 2:00 AM.
Set backlight operation with + or — buttons
Default setting is ON.
OFF will turn display backlight o after 5 minutes of keypad inactivity.
Return to general display
Only appears on
units that support a
backlit display
Set hour of regen time with + or — buttons
If IMMEDIATE REGEN is set (see Service OEM page), regen will be
immediate once total capacity is exhausted and ON ZERO will be displayed.
Default setting is 12:00 AM.
Set minutes of regen time with + or — buttons
If IMMEDIATE REGEN is set (see Service OEM page), regen will be
immediate once total capacity is exhausted and ON ZERO will be displayed.
Default setting is 12:00 AM.
Set backlight operation with + or — buttons
Default setting is ON.
OFF will turn display backlight o after 5 minutes of keypad inactivity.
Return to general display
Only appears on
units that support a
backlit display
Set days between a regeneration with + or — buttons
Adjustable from 1-28 days, or OFF.
Default setting is 3.