Watlow EZ-ZONE
®
PM Integrated Controller • 56 • Chapter 6 Setup Page
[ALM]
[`Set] Alarm Menu
[```1] to [```4]
[ALM] Alarm
[`A;ty] Type
[`sr;a] Source Function A
[`is;;A] Source Instance A
[`A;hy] Hysteresis
[`a;Lg] Logic
[`A;SD] Sides
[`a;LA] Latching
[`A;bL] Blocking
[`a;Si] Silencing
[A;dsp] Display
[`A;dL] Delay
[CUrr]
[`Set] Current Menu
[```1]
[CUrr] Current
[`C;Sd] Sides
[`C;Ur] Read Enable
[`C;dt] Detection Threshold
[`C;SC] Input Current Scaling
[C;ofs] Heater Current Offset
[`C;Si] Output Source Instance
[MAt]*
[`Set] Math Menu
[```1]
[MAt] Math
[``Fn] Function
[SFn;E] Source Function E
[`Si;E] Source Instance E
[`S;Lo] Input Scale Low
[`S;hi] Input Scale High
[`r;Lo] Output Range Low
[`r;hi] Output Range High
[`FiL] Filter
[`SoF]*
[`Set] Special Output Function Menu
[```1]
[`SoF] Special Output Function
[``Fn] Function
[SFn;A] Source Function A
[`Si;A] Source Instance A
[SFn;B] Source Function B
[`Si;B] Source Instance B
[Pon;A] Power On Level A
[PoF;A] Power Off Level A
[Pon;b] Power On Level B
[PoF;b] Power Off Level B
[`on;t] Minimum On Time
[`of;t] Minimum Off Time
[``t;t] Valve Travel Time
[``db] Dead Band
[`fUn]
[`Set] Function Key Menu
[```1] to [```2]
[`fUn] Function Key
[`leu] Level
[``Fn] Digital Input Function
[``fi] Instance
[gLbL]
[`Set] Global Menu
[```1]
[gLbl] Global
[`C_F] Display Units
[AC;LF] AC Line Frequency
[r;typ] Ramping Type
[p;typ] Profile type
[`gse] Guaranteed Soak Enable
[gsd1] Guaranteed Soak Devia-
tion 1
[gsd2] Guaranteed Soak Devia-
tion 2
[`si;a] Source instance A
[`si;b] Source instance B
[poti] Power Out Time
[C;led] Communications LED Act-
ion
[2one] Zone Action
[Chan] Channel Action
[d;prs] Display Pairs
[`d;ti] Menu Display Timer
[Usr;s] User Save
[Usr;r] User Restore
[COM]
[`Set] Communications Menu
[```1] to [```2]
[COM] Communications
[pCol] Protocol
[`a;ds] Standard Bus Address
[bAUd] Baud Rate
[`PAr] Parity
[M;hL] Modbus Word Order
[iP;m] IP Address Mode
[ip;f1] IP Fixed Address (Part 1)
[ip;f2] IP Fixed Address (Part 2)
[ip;f3] IP Fixed Address (Part 3)
[ip;f4] IP Fixed Address (Part 4)
[ip;f5] IP Fixed Address (Part 5)
[ip;f6] IP Fixed Address (Part 6)
[ip;51] IP Fixed Subnet (Part 1)
[ip;52] IP Fixed Subnet (Part 2)
[ip;53] IP Fixed Subnet (Part 3)
[ip;54] IP Fixed Subnet (Part 4)
[ip;s5] IP Fixed Subnet (Part 5)
[ip;s6] IP Fixed Subnet (Part 6)
[ip;g1] IP Fixed Gateway (Part 1)
[ip;g2] IP Fixed Gateway (Part 2)
[ip;g3] IP Fixed Gateway (Part 3)
[ip;g4] IP Fixed Gateway (Part 4)
[ip;g5] IP Fixed Gateway (Part 5)
[ip;g6] IP Fixed Gateway (Part 6)
[mb;e] Modbus TCP Enable
[eip;e] EtherNet/IP Enable
[ao;nb] Output Assembly Size
[ai;nb] Input Assembly Size
[`C_f] Display Units
[map] Data Map
[`nu;s] Non-volatile Save
[`rtC]*
[`Set] Real Time Clock
[hoUr] Hour
[min] Minute
[dow] Day of Week
* Available with PM4, 8 and 9 models only