Watlow EZ-ZONE
®
PM Integrated Controller 57 Chapter 6 Setup Page
Setup Page
Dis-
play
Parameter name
Description
Range Default
Parameter
Appears
in Menu
When
Modbus Rela-
tive
Address
CIP
Class
Instance
Attribute
hex (dec)
Profibus
Index
Data
Type
&
Read/
Write
[``Ai]
[`Set]
Analog Input Menu
[`Sen]
[ SEn]
Analog Input (1 to 2)
Sensor Type
Set the analog sen-
sor type to match the
device wired to this
input.
Note:
There is no open-sensor
detec-
tion for process inputs.
[`oFF] Off (62)
[``tC] Thermocouple (95)
[`mu] Millivolts (56)
[uolT] Volts dc (104)
[`MA]
Milliamps dc (112)
[r0;1H]RTD100Ω(113)
[r1;0H]RTD1,000Ω(114)
[`Pot]Potentiometer1kΩ
(155)
[thEr] Thermistor (229)
Off Always Instance 1
Map 1 Map 2
368 368
Instance 2
Map 1 Map 2
448 458
0x68 (104)
1 to 2
5
3 uint
RWES
[`Lin]
[ Lin]
Analog Input (1 to 2)
Linearization
Set the linearization
to match the thermo-
couple wired to this
input.
[```b] B (11) [```H] K (48)
[```C] C (15) [```n] N (58)
[```d] D (23) [```r] R (80)
[```E] E (26) [```S] S (84)
[```F] F (30) [```t] T (93)
[```J] J (46)
J
Sensor Type
is set to
Thermo-
couple.
Instance 1
Map 1 Map 2
370 370
Instance 2
Map 1 Map 2
450 460
0x68 (104)
1 to 2
6
4 uint
RWES
[`Rt;L]
[ rt.L]
Analog Input (1 to 2)
RTD Leads
Set to match the
number of leads on
the RTD wired to
this input.
[```2] 2 (1)
[```3]
3 (2)
2 Sensor Type
is set to
RTD 100
ΩorRTD
1,000Ω.
Instance 1
Map 1 Map 2
372 368
Instance 2
Map 1 Map 2
452 462
0x68 (104)
1 to 2
7
- - - - uint
RWES
[Unit]
[Unit]
Analog Input (1 to 2)
Units
Set the type of units
the sensor will mea-
sure.
[`A;tP] Absolute Tempera-
ture (1540)
[``rh]
Relative Humidity
(1538)
[`Pro]
Process (75)
[PWr]
Power (73)
Process Sensor Type
is set to
Millivolts,
Volts, Mil-
liamps or
Potentiom-
eter1kΩ.
Instance 1
Map 1 Map 2
- - - - 442
Instance 2
Map 1 Map 2
- - - - 532
0x68 (104)
1 to 2
0x2A (42)
5 uint
RWES
[`S;Lo]
[ S.Lo]
Analog Input (1 to 2)
Scale Low
Set the low scale for
process inputs. This
value, in millivolts,
volts or milliamps,
will correspond to
the Range Low out-
put of this function
block.
-100.0 to 1,000.0 0.0 Sensor Type
is set to
Millivolts,
Volts, Mil-
liamps or
Potentiom-
eter1kΩ.
Instance 1
Map 1 Map 2
388 388
Instance 2
Map 1 Map 2
468 478
0x68 (104)
1 to 2
0xF (15)
6 float
RWES
[`S;hi]
[ S.hi]
Analog Input (1 to 2)
Scale High
Set the high scale for
process inputs. This
value, in millivolts,
volts or milliamps,
will correspond to
the Range High out-
put of this function
block.
-100.0 to 1,000.0 20.0 Sensor Type
is set to
Millivolts,
Volts, Mil-
liamps or
Potentiom-
eter1kΩ.
Instance 1
Map 1 Map 2
390 390
Instance 2
Map 1 Map 2
470 480
0x68 (104)
1 to 2
0x10 (16)
7 float
RWES
Note:
Some values will be rounded off to fit in the four-character display. Full values can be read with other
interfaces.
* Available with PM4, PM8 and PM9 models only
R: Read
W: Write
E:
EE-
PROM
S:
User
Set